III. INSTALLATION

CPU

III. INST

ALLA

TION

2. Mount the Heatsink: Place the SEC cartridge face down on a flat surface and lay

the heatsink flush on the back (metal side) of the SEC cartridge. Be sure that the
heatsink is firmly pressed against the SEC cartridge. When correctly installed,
no light can be seen between the thermal pad of the heatsink and the SEC car-
tridge.

IMPORTANT: The heatsinks must not be more than 2.8 cm (1.1 inch) thick.

SEC Cartridge with Heatsink (Top View)

Push each end of the clamps until they lock

The thermal pad & SEC cartridge should not have a gap!

Lock

Lock

WARNING!

If the heatsink is not mounted tightly against the SEC cartridge,

the CPU will overheat. You may install an auxiliary fan to provide adequate
circulation across the processor’s passive heatsink.

3. Insert the SEC Cartridge: Push the SEC cartridge’s two locks inward until

you hear a click (the preceding picture shows the locks in the outward position
and inward in the picture below). With the heatsink facing the motherboard’s
chipset, press the cartridge gently but firmly until it is fully inserted. (NOTE:
The procedures shown here are for installing the AAVID heatsink with fan.)

Push lock inward