Transmitter functions

The receiver uses a computer-based learn routine to learn the transmitter buttons. This makes it

possible to assign any specific transmitter button, or combination of buttons, to any receiver

function. The transmitter initially comes programmed with the Standard Configuration, but may

also be customized by an authorized dealer. The transmitter buttons indicated in all of the

instructions in this manual correspond to a Standard Configuration transmitter.

S

TANDARD CONFIGURATION

Button

Pressing

duration

Action Confirmations

1 sec.

The locking function and the deactivation of the
Panic mode is controlled by pressing this button.

Parking lights flashes once.

Horn honks once on every

commands.

5 sec.

The panic mode engages when this button

is depressed for at least 5 seconds.

Panic mode engages.

1 sec.

The unlocking function and the deactivation of

the Panic mode is controlled by pressing this button for 1 second.

Parking lights flashes twice.

Horn honks twice on every

commands.

5 sec.

The panic mode engages when this button

is depressed for at least 5 seconds.

Panic mode engages.

1 sec.

Pressing this button before transmitting any commands

momentarily disables all the audible confirmations.

Audible confirmations

are deactivated.

1.5 sec.

An optional auxiliary function, such as trunk release,

can be controlled by pressing this button for 1.5 seconds.

Parking lights flashes three times.

Horn honks three times on every

commands.

The auxiliary output controls :

1 sec.

An optional auxiliary convenience or expansion function that you have added

to your system can be activated by pressing these buttons simultaneously.

Parking lights flashes four times.

&

The auxiliary output controls :

Using your system

L

OCKING

Pressing

for one second activates the starter kill (optional) and locks the doors (if connected).

The horn will honk (if connected) and the parking lights will flash once. While the starter kill is

enabled, the status LED will flash once per second. The Failsafe

®

Starter Kill (if installed) will

prevent the vehicle’s starter from cranking.

Note: Manually locking the vehicle does not activates

the Failsafe

®

system, it will only lock the doors.

The system can also be programmed to activate the optional Failsafe

®

Starter Kill automatically

(called AED for Automatic Engine Disable). If the system has been programmed for AED enabled,

the Failsafe

®

Starter Kill will automatically activate 30 seconds after the ignition has been turned

© 2006 Astroflex Electronics – All rights reserved

2