Stove installation, Mobile home requirements – Avalon Stoves 745 User Manual

Page 13

Advertising
background image

Stove Installation

(for qualified installers only)

13

Travis Industries

93508133

4 020509

Mobile Home Requirements

•

Outside air must be installed - see "Outside Air Requirements" on page 11

•

Chimney connector and chimney must be one of the following types:

• DURAVENT model DVL with DURATEC chimney
• DURAVENT model DVL with DURA-PLUS chimney
• AMERI-TEC model DCC with model HS chimney
• SECURITY model DL with SECURITY model ASHT or S2100 chimney
• METAL-FAB model DW with TG chimney

• GSW Double Wall Chimney Connector with Super Chimney Twenty-One
• SELKIRK METALBESTOS model DS connector with model SSII chimney
• I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
• Standard Masonry Chimney with any one of the above listed connectors

NOTE: Reduced clearance connectors may not connect to the flue collar – order an appliance

adapter for the connector being used.

•

Stove placement must maintain the following clearances to combustibles (drywall, furniture, etc.)

Minimum Clearance
(See the illustration below)

7 4 5

R e d u c e d

C l e a r a n c e
C o n n e c t o r

7 9 0

R e d u c e d

C l e a r a n c e
C o n n e c t o r

A

Sidewall to stove

11"

11"

B

Backwall to stove

13"

8 1/2"

C

Cornerwall to stove

7 1/2"

7 1/2"

D

Connector to sidewall

19 1/2"

19 1/2"

E

Connector to backwall

9"*

8 3/4"

F

Connector to cornerwall

11"*

15"

*

These are minimum clearances, not installation dimensions. Connector position will vary
depending upon brand. First establish the stove clearances, install the 45° connector to the stove, then
determine the position of the connector.

Straight Installations

a

b

d

e

Corner Installations

c

f

NOTE:
Measure clearances to the stove top.

•

If using offsets, use the connector clearance listed to the
right, not the connector manufacturer's
c l e a r a n c e
.

•

The appliance must be secured to the floor (consult your
building official). Secure the outside air boot to the floor
and stove to insure the stove does not dislocate.

•

Mobile home installations require a spark arrester at the
chimney termination.

•

The appliance must be grounded to the chassis of the
mobile home (consult your building official).

WARNING:

DO NOT INSTALL IN SLEEPING ROOM.

CAUTION:

THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.

Minimum Stove
Clearance
(as outlined above)

12-1/4”
Min.

Minimum Connector
Clearance
(as outlined above)

Advertising
This manual is related to the following products: