About, Resetting to the factory default settings, Unit connectors – Axis Communications FD-R M12 User Manual

Page 30

Advertising
background image

30

AXIS 209FD/FD-R/FD-R M12

Logs & Reports - when contacting Axis support, please be sure to provide a valid Server Report with

your query.

View Information - The Log file, the Server Report and the Parameter List all provide valuable

information for troubleshooting and when contacting Axis support.

Configuration

Log Level for Log Files - from the drop-down list, select the level of information to be added to the

Log file

Log Level for Email - from the drop-down list, select the level of information to send as email and

enter the destination email address.Advanced

Scripting is an advanced function that provides the means for customizing and using scripts.

Caution!

The scripting function is a very powerful tool. Improper use may cause unexpected behavior or even loss of

contact with the unit. If a script does cause problems, reset the unit to its factory default settings (in which

case, a previously saved backup file will be useful for returning the unit to its latest configuration).

Axis strongly recommends that you do not use this function unless you fully understand its

consequences. Axis support provides no assistance for customized scripts.

For more information, please visit the Developer pages at www.axis.com/developer

Plain Config - this function is for the advanced user with previous experience of configuring Axis cameras.

All parameters can be set and modified from this page. Help is available via the links on the standard setup

pages.

About

Third Party Software Licenses - Click View licenses for a list of the licensed software used in the
AXIS 209FD/FD-R Network Camera.

Resetting to the factory default settings

To reset the camera to the original factory default settings, go to the System Options > Maintenance web

page (as described in Maintenance, on page 29) or use the Control button, which is found inside the camera

cover (see Overview, on page 6) as described below:

Using the Control Button
To reset the camera to the factory default settings using the Control Button:

1. Remove the camera’s cover.
2. Disconnect the network to remove power.
3. Press and hold the Control button while reconnecting the cable.
4. Keep the Control button pressed until the Status Indicator color changes to amber (this may take

up to 15 seconds).

5. Release the Control button.
6. When the Status Indicator changes to Green (which may take up to 1 minute), the process is

complete and the camera has been reset. The unit will now have the default IP address

192.168.0.90

Unit connectors

(AXIS 216FD) network connector - Female RJ-45 Ethernet connector for 10BaseT/100BaseTX. Supports

Power over Ethernet. Using shielded cables is recommended.