Controlling the multiple monitors, Connecting the cable, Rs-232c configurations – LG L1730SF User Manual

Page 21: Communication parameter

Advertising
background image

A20

Controlling the Multiple Monitors

Connecting the cable

Connect the RS-232C cable as shown in the picture.

* The RS-232C protocol is used for communication between the PC and monitor.

You can turn the monitor on/off, select an input source or adjust the OSD menu

from your PC.

Baud Rate : 9600bps (UART)
Data Length : 8bits
Parity Bit : NONE
Stop Bit : 1bit
Flow Control : NONE
Use a straight cable

Use this method to connect several monitors to a single PC.
You can control several monitors at a time by connecting them to a single PC.

Communication Parameter

PC

0utput

0utput

0utput

0utput

< RS-232C Distributor- (Not included) >

Input

7-Wire Configurations (Standard RS-232C cable)

RXD
TXD
GND
DTR
DSR
RTS
CTS

TXD
RXD
GND
DSR
DTR
CTS
RTS

PC

Monitor

2
3
5
4
6
7
8

2
3
5
4
6
7
8

D-Sub 9 D-Sub 9

(Female) (Male)

3-Wire Configurations (Not Standard)

RXD
TXD
GND
DTR
DSR
RTS
CTS

TXD
RXD
GND
DSR
DTR
CTS
RTS

PC

Monitor

2
3
5
4
6
7
8

2
3
5
4
6
7
8

D-Sub 9 D-Sub 9

(Female) (Male)

RS-232C Configurations

Advertising