Service, Specifications – American Power Conversion 620 User Manual

Page 3

Advertising
background image

Service

If the UPS requires service do not return it to the dealer!

Follow these steps:

1. Use the Troubleshooting section of the Quick Reference Guide to eliminate

common problems.

2. Verify that no circuit breakers are tripped. A tripped circuit breaker is the most

common UPS problem!

3. If the problem persists, call customer service or visit the APC Internet Website

(www.apcc.com).

•

Note the model number of the UPS, the serial number, and the date purchased. A
technician will ask you to describe the problem and try to solve it over the phone,
if possible. If this is not possible the technician will issue a Return Merchandise
Authorization Number (RMA#).

•

If the UPS is under warranty, repairs are free. If not, there is a repair charge.

4. Pack the UPS in its original packaging. If the original packing is not available,

ask customer service about obtaining a new set.

•

Pack the UPS properly to avoid damage in transit. Never use Styrofoam beads for
packaging. Damage sustained in transit is not covered under warranty.

•

Include a letter with your name, RMA#, address, copy of the sales receipt,
description of the trouble, your daytime phone number, and a check (if
necessary).

5. Mark the RMA# on the outside of the package

6. Return the UPS by insured, prepaid carrier to the address given to you by

Customer Service.

North & South America

Europe

APC

APC

132 Fairgrounds Road

Ballybritt Business Park

West Kingston, Rhode Island 02892 USA

Galway, Ireland 10800-702000

1-800-800-4APC/1-401-789-5735

353-91-702020

Internet: http://www.apcc.com

E-Mail: [email protected]

E-Mail: [email protected]

Specifications

420 VA

620 VA

Acceptable input voltage

0 - 320 VAC

Input voltage (on-line operation)*

165 - 283 VAC

Output voltage *

208 - 253 VAC

Input Over Current Protection

Resettable circuit breaker

Frequency limits (on-line operation)

47 - 63 Hz (autosensing)

Transfer time

4 ms typical, blackout response time

Maximum load

420 VA

260 W

620 VA

390 W

On-battery output voltage

230 VAC

On-battery frequency

50 or 60 Hz, ±0.1 Hz; unless synchronized to utility

during brownout

On-battery waveshape

Stepped sine-wave

Output Over Current Protection

Overcurrent and short-circuit protected, latching

shutdown on overload

Battery type

Spill proof, maintenance free, sealed lead-acid

Typical battery life

3 to 6 years, depending on number of discharge

cycles and ambient temperature

Typical recharge time

2 to 5 hours from total discharge

Operating temperature

0 to +40

°

C (+32 to +104

°

F)

Storage temperature

-15 to +45

°

C (+5 to +113

°

F)

Operating and storage relative humidity

0 to 95%, non-condensing

Operating elevation

0 to +3,000 m (0 to +10,000 ft)

Storage elevation

0 to +15,000 m (0 to +50,000 ft)

Audible noise at 1 m (3 ft)

<45 dBA

Size (H x W x D)

16.8 x 11.9 x 36.8 cm

(6.6 x 4.7 x 14.5 in.)

Weight - net (shipping)

7.30 (9.12) kg

16.108 (20.10) lb.

10.53 ( 12.34) kg

23.51 (27.21) lb.

Safety and approvals

VDE licensed to EN50091 and EN60950

EMC certification

EN55022

Electromagnetic immunity

IEC 801-2 level IV, 801-3 level III, 801-4 level IV

* User-adjustable through PowerChute® (see software documentation)