ELECTRICAL CONNECTION

INSTRUCTIONS

ELECTRICAL TEST PROCEDURE

An electrical socket must be provided within 6 feet of the LH side of the appliance and easily accessible to the user to
disconnect. Do not position socket above the appliance.

Electric Shock Hazard

Electrical Grounding is required on this appliance.

Do Not connect to the electrical supply until the appliance is permanently grounded.

Disconnect the power to the junction box before making the electrical connection.

This appliance must be connected to a grounded, metallic, permanent supply or a grounding connector should
be connected to the grounding terminal or wire lead on the appliance.

Failure to follow these instructions could result in death or serious injury.

This range must be supplied with a 240V, 60 Hz power supply and connected to an individual, properly grounded branch
circuit protected by a circuit breaker of time delay fuse. At 240V, it is rated 2.5 kW, 13 Amps. Electric hook-up must be
done by licensed electrician. This unit must be installed according to local code, or in the absence of local codes, the
National Electrical Code for the country of installation.

Wire sizes (COPPER WIRE ONLY) and connections must conform with the rating of the range (30-amperes).

z

The wiring diagram is located on the back of the L.H. door.

THIS APPLIANCE MUST HAVE THE FACILITY OF BEING COMPLETELY ISOLATED FROM THE ELECTRICITY
SUPPLY.

THE APPLIANCE MUST BE COMPLETELY ISOLATED FROM THE ELECTRICITY SUPPLY BEFORE
SERVICING.

WARNING

Electrical Grounding Instructions

This appliance is equipped with a grounding pin for your protection against a shock hazard. The power cord should be
plugged directly into a receptacle. Do not use an extension cord.

Hand this Owners Manual to the user for retention and instruct in the safe operation of the appliance.

Also advise the user that, for continued efficient and safe operation of the appliance, servicing is carried out at intervals
recommended by the Aga distributor.

Final Electrical Test - Electric Voltage - Withstand Test

Procedure:
(Earth Appliance Test Simulation)

1. Select 1200 volts Flash Test on test equipment.
2. Plug in supply plug into the test equipment.
3. Depress the ‘Test Button’ for 1 second.
4. A ‘Pass’ light will illuminate.
5. If the appliance fails this test, re-check all circuits and correct the fault and retest the range.
6. Disconnect from the test equipment and connect range to its permanent supply.
7. A full load test will be performed using a clamp meter connected to the incoming supply.

NOTE: The test results 10.5 -11 amps normal operation.

8. Make note of results and disconnect all leads.