AMCC 3WARE 720-0138-00 User Manual

Page 145

Advertising
background image

www.3ware.com

137

to another controller. Compare to Delete, which erases all unit
configuration information from the drive.

•

Exportable unit or drive

. Exportable units and drives are those that will

be available to the operating system when you boot your computer.

•

Fault tolerant

. A RAID unit which provides the ability to recover from a

failed drive, either because the data is duplicated (as when drives are
mirrored) or because of error checking (as in a RAID 5 unit).

•

Firmware.

Computer programming instructions that are stored in a read-

only memory on the controller rather than being implemented through
software.

•

Grown defect.

Defects that arise on a disk from daily use.

•

Hot spare.

A drive that is available, online, and designated as a spare.

When a drive fails in a redundant unit, causing the unit to become
degraded, a hot spare can replace the failed drive automatically and the
unit will be rebuilt.

•

Hot swapping

. The process of removing a disk drive from the system

while the power is on. Hot swapping can be used to remove units with
data on them, when they are installed in hot-swap carriers. This is referred
to as array roaming. Hot swapping can also be used to remove and
replaced failed drives when a hot-swap carrier is used.

•

I²C-(or Inter-IC) bus

. A two-wire serial bus solution used as a control,

diagnostic, environmental, and power management for EMS (enclosure
management services).

•

Import a unit

. Attach a set of disk drives with an existing configuration to

a controller and make the controller aware of the unit. Does not affect the
data on the drives.

•

Initialize.

For 3ware SATA RAID controllers, initialize means to put the

redundant data on the drives of redundant units into a known state so that
data can be recovered in the event of a disk drive failure. For RAID 1 and
10, initialization copies the data from the lower port to the higher port.
For RAID 5, initialization calculates the RAID 5 parity and writes it to
disk (background initialization). This is sometimes referred to as
resynching, and does not erase user data.

•

Logical Units.

This term is used in the 3ware CLI. It is usually shortened

to “units.” These are block devices presented to the operating system. A
logical unit can be a one-tier, two-tier, or three-tier arrangement. Spare,
and Single logical units are examples of one-tier units. RAID 1 and RAID
5 are examples of two-tier units and as such will have sub-units. RAID 10
is an example of a three-tier unit and as such will have sub-sub-units.

•

Migration.

The process of changing the characteristics of a unit. The

change can be to expand the capacity of the unit (OCE), change the stripe

Advertising