Windows installation troubleshooting

When working properly, the ATTO Technology Banner should appear shortly after booting the computer,

as shown in

Figure 7

.

Figure 7 ATTO Technology Banner

The adapter will be listed as ATTO ExpressPCI UL5D SCSI Adapter in the Windows Device

Manager, as shown in

Figure 8

.

Figure 8 Adapter in Windows Device Manager
Table 4 Windows installation troubleshooting table

Symptoms

Troubleshooting steps

The computer will not boot

past its Power On Self Test

when the host adapter is

installed

•

Check the adapter installation (see

Investigating the adapter

installation

, page 31).

•

Disconnect any SCSI devices from the host adapter and reboot the

computer. If this resolves the issue, check the SCSI cables and devices

(see

Investigating the SCSI cables and devices

, page 31).

•

If the computer still does not boot, try installing the host adapter in a

different computer. If the host adapter works in the new computer, report

this as a possible interoperability issue between the host adapter and

the computer. If the problem follows the host adapter, replace it with

a new adapter.

•

Verify that the latest version of the computer BIOS is installed. Use

caution when updating the computer’s BIOS. A mistake could leave

the system in an unusable state.