HP Matrix Operating Environment Software User Manual

Page 47

Advertising
background image

3.

Select the Properties tab.

a.

Change the current volume name by typing the preferred name in the Name field.

b.

Change the description by typing the preferred information in the Description field.

c.

Select a service group from the Service Group list.

d.

Change the volume serial number by typing the correct information into the Volume Serial
Number field.

e.

Enter the preferred capacity into the Capacity field, then select the units of measure (for
example, GB or TB) from the capacity list.

f.

Select the RAID type from the list.

g.

If you want to disable fulfillment and automation, clear the Enable fulfillment and automation
box.

h.

Click the OK button to save modifications, or select another tab to continue.

NOTE:

The array name and some other information displays, but cannot be modified using this
procedure.

Modifying presentation of the volume service (Presentation tab)

The Presentations screen enables you to view or specify presentation settings for a managed or
unmanaged volume service. The presentation of unmanaged volumes can be modified using SPM.
The presentation of managed volumes is discovered from the array, can be viewed in SPM, but can
be modified in SPM only with the appropriate permissions.

Viewing presentation settings of a managed volume service

To view the presentation settings of a managed volume service from SPM:

1.

From the Navigation tree, click Volume Services, then click on the preferred volume service in
the List View.

2.

Click the Actions Properties button at the bottom of the screen. (Alternatively, right-click the volume
service in the List View and select Properties.)

The Volume Properties dialog box appears.

3.

Select the Presentation tab.

Three tables appear in the Presentations window. When a volume is selected (highlighted) in the
Volume Presentations table, information corresponding to that volume appears in the Presented
to Initiators and Presented by Targets tables.

4.

If preferred, click the Refresh from Array button to update the displayed data.

NOTE:

There may be a short delay between the time a volume configuration change is made on
the array and when the information is available to SPM. If the volume change is not reflected
in the catalog after a refresh operation, wait a few minutes and refresh the catalog again.

HP Storage Provisioning Manager (SPM) Version 1.2 User Guide

47