HP Smart Update Manager User Manual

Page 9

Advertising
background image

HP deliverable

HP SUM command

Description

Scenario

Target2 -username

User1 -password

PW1

◦

HP Integrity BL8x0c
i2, rx2800 i2, and
Superdome 2 Servers
Bundles for Windows
and Linux

•

Need to update all
enclosure firmware

•

Need to target VMware
host servers

◦

HP Service Pack for
ProLiant

•

Offline:

SmartStart Scripting
Toolkit (G7 and older)

Scripting Toolkit (Gen8
and older)

The HP SPP and Smart
Update Firmware DVD take
care of this automatically

Use this scenario when you:

Automatic Deployment to
one or more servers in a HP
BladeSystem enclosure

•

Online:

None

•

Do not have an operating
system installed on a
server blade

Use the HP Smart Update
Firmware DVD or HP SPP

•

Offline:

◦

HP Smart Update
Firmware DVD

•

Want an automatic way
to deploy firmware
updates

with embedded HP SUM to
deploy firmware updates to
one or more blades
automatically.

◦

HP Service Pack for
ProLiant

•

Do not require log files
or user interaction with
the installation process

•

Want to update multiple
blades in an enclosure in
a single operation

The same scenario as shown
in the “Interactive, graphical

Update an existing enclosure
manually

•

Online:

•

Windows:

hpsum

◦

HP Smart Update
Firmware DVD

deployment to a remote
host” or “Scripted

For more information, see
the HP CloudSystem Matrix

•

Linux:

./hpsum

deployment to a remote
host” scenarios discussed
previously in this table

◦

HP Service Pack for
ProLiant

Compatibility website at

http://www.hp.com/go/
matrixcompatibility

.

•

Offline:

◦

HP Smart Update
Firmware DVD

◦

HP Service Pack for
ProLiant

Deploying firmware for ProLiant servers using the Service Pack for ProLiant

SPP is a re-packaging of HP ProLiant system software and firmware for ProLiant ML/DL/SL servers
and their options, and BladeSystem enclosures including OA,VC, and 3 GB SAS switches running
supported Windows, Linux, and VMware operating systems. The single SPP image contains a
comprehensive collection of firmware and system software components including drivers, agents,
non-agents, utilities, and firmware that is tested, managed, and deployed together as a single
solution.

NOTE:

HP SUM can detect updates that are available for a VMware server and generate reports,

it cannot deploy updates.

SPP includes HP SUM for deployment of the SPP components.

For a complete list of HP ProLiant systems and software supported by SPP, see the HP Service Pack
for ProLiant Release Notes
on the HP SPP website at

http://www.hp.com/go/spp/documentation

.

Deploying HP SUM

9

Advertising