Possible values

Description

Parameter

YES

, NO

Allows the installation to proceed on a
Superdome 2 target even when warnings
are returned during analysis.

IGNOREWARNINGS

Superdome 2 servers only

ALL

, COMPLEX, PARTITIONS

This argument determines which
Superdome 2 firmware is updated.

UPDATETYPE

Superdome 2 servers only

For example: DEVICELIST = npar1,
blade1/1

Use this argument when the
UPDATETYPE=PARTITIONS

. This

argument specifies the subset of partitions

DEVICELIST

Superdome 2 servers only

or blades to update when you do not
want to update all partitions. Valid
devices are: npar(number) and
blade(enc)/(bay)

.

For example: REBOOTLIST = npar1,
npar2

Use this argument when the
UPDATETYPE= ALL

or UPDATETYPE=

PARTITIONS

. This argument specifies

REBOOTLIST

Superdome 2 servers only

specific partitions to reboot after the
partition firmware has been updated.
Valid npar values are npar(number).

Examples of the HP SUM input file include the following:

REBOOTALLOWED = YES

REBOOTREQUIRED = NO

REBOOTMESSAGE = "Server is going down for a reboot"

REBOOTDELAY = 15

COMPONENTSLIST = cp001234.exe, cp001235.exe

BUNDLESLIST = bp001234.xml

ALLOWUPDATEBUNDLE = YES

SKIPTARGET = NO

IGNOREERRORS = ServerNotFound, FailedDependencies

SOURCEPATH = c:\pkgsource1

USELATEST = YES

SILENT = YES

OPTIONS = /f:rom

[TARGETS]

HOST = schinta1

HOST = schinta2

UID = root

PWD = root123

HOST = 234.567.765.432

[END]

USAGE: hpsum /inputfile <path:\inputfile.txt>

Examples of inputfile.txt file:

Example: The two targets are passed to be updated. The targets do not necessarily have to be
OAs. They can be any target that HP SUM supports.

DRYRUN = YES

Input files

51

Advertising