Calibrating multiple systems at once, Calibrating power within a scenario – HP Matrix Operating Environment Software User Manual

Page 103

Advertising
background image

Known problem: Collecting an iLO2 license:

One of the steps in the checklist is to collect the iLO2 license. The following are known issues
with this step:

You must be able to ping the iLO2 from the CMS using only the system name (not the fully
qualified domain name).
— The HP SIM License Manager uses the system name, not the fully qualified domain

name, regardless of system settings.

— Systems in the same DNS zone as the CMS will work fine.
— Systems in a different DNS zone will need to have the DNS suffix for the managed

nodes iLO2 added to the IP configuration of the CMS.

You must be able to access the iLO2 via SSH from the CMS.
— HP SIM License Manager collects iLO2 licenses via SSH.
— There is a maximum of 2 concurrent SSH sessions for iLO2.
— iLO2 SSH sessions may be abandoned and not reclaimed. This causes the iLO2 SSH to

deny new connections, and the HP SIM License Manager iLO2 license collection to fail.
If this occurs, reset the iLO2 (that is, use the reset button at the bottom of the iLO2
diagnostics page in the iLO2 web GUI).

Calibrating multiple systems at once

On the Visualization tab, select the check boxes to the left of the desired systems, and select
Configure

Calibrate Power (All Selected Systems) on the Virtualization Manager menu bar.

Procedure 5-94 Selecting a calibration option for multiple systems

1.

Click the radio button to the left of the desired calibration option.

2.

Supply values for idle and maximum power usage when manual calibration is selected. (See

“Power calibration calculations” (page 125)

for assistance in determining valid values for

particular systems.)

Procedure 5-95 Confirming system selection

1.

Review the list of systems in the Selected Systems table.

2.

Optional: Click the remove link to delete a system from the table and remove it from the
calibration operation.

3.

Select Apply or OK to set the new calibration value for all systems remaining in the table .

Want to calibrate a single system at a time?:

For each system in the Selected Systems table that you want to calibrate individually, click the
details

link to open the Calibrate Power (Single System) screen for that system.

TIP:

If you elect to individually calibrate some of the systems in a multiple listing, but not all,

first calibrate the individual systems, and then remove them from the Selected Systems table.
The systems remaining in the table list are those to which you can apply a different set of values
at once using the control buttons on this screen.

Calibrating power within a scenario

This screen allows you to define the power calibration parameters for simulated systems in a
scenario. These power settings specify whether or not to calibrate power, and if so, which settings
to use for the calibration.

Working with power

103