Optional scsi drive controller – HP Netserver L Server series User Manual

Page 30

Advertising
background image

Chapter 3

Installing Mass Storage Devices

24

Figure 3-5. Removing a Hot Swap Drive

CAUTION

To prevent overheating or excessive electromagnetic
radiation, use the filler panels to fill the unused drive bays. If
the filler panels are left out of empty drive bays while the
Netserver is operating, thermal damage and/or excessive EMI
could occur.

Optional SCSI Drive Controller

Typically, this option is only used when hardware mirroring the Hot Swap SCSI
drives. To change control of the SCSI drives requires installation of a supported
HP NetRAID controller board and moving the connection of the existing SCSI
cable. One end is moved from the SCSI A cable connection on the system board
to the SCSI connector on the supported HP NetRAID Controller board.

1. Refer to Chapter 5, "Installing Additional Boards," to access the Netserver.

CAUTION

Don't disconnect the SCSI cable on the SCSI backplane board.
This cable end remains connected while moving the other end
of the cable at the SCSI A connector on the system board.

2. Disconnect the SCSI cable end connected to the SCSI A cable connection on

the system board. See Figures 3-6 and 3-7.