Cascade function and configuration files – HP XP RAID Manager Software User Manual

Page 87

Advertising
background image

Correspondence of the configuration file and mirror descriptors

The group name and MU# which are described in HORCM_DEV of a configuration definition file
are assigned the corresponding mirror descriptors, as outlined in

Table 18 (page 87)

. "Omission

of MU#" is handled as MU#0, and the specified group is registered to MU#0 on Business Copy
and Continuous Access Synchronous. Also, the MU# that is noted for HORCM_DEV in

Table 18 (page 87)

reflects a random numbering sequence (for example, 2, 1, 0).

Table 18 Mirror Descriptors and Group Assignments

Cnt Ac-J
Only

Business Copy
(Snapshot) Only

MU#0

HORCM_DEV Parameter in Configuration File

MU#1-#3

MU#1-#2

BC

Cnt Ac-S/
Cnt Ac-J

(MU#3-#63)

-

-

oradev1

oradev1

HORCM_DEV

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1

-

oradev11

oradev1

oradev1

HORCM_DEV

oradev21

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1

Oradb1 oradev11 CL1-D 2 1 1

Oradb2 oradev21 CL1-D 2 1 2

-

oradev21

oradev11

oradev1

HORCM_DEV

oradev31

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1

Oradb1 oradev11 CL1-D 2 1 0

Oradb2 oradev21 CL1-D 2 1 1

Oradb3 oradev31 CL1-D 2 1 2

-

-

oradev1

-

HORCM_DEV

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1 0

-

oradev11

oradev1

-

HORCM_DEV

oradev21

#dev_group dev_name port# TargetID LU# MU#

Oradb oradev1 CL1-D 2 1 0

Oradb1 oradev1 CL1-D 2 1 1

Oradb2 oradev21 CL1-D 2 1 2

oradev21

-

oradev11

oradev1

HORCM_DEV

#dev_group dev_name port# TargetID LU# MU#

oradev31

Oradb oradev1 CL1-D 2 1

oradev41

Oradb1 oradev11 CL1-D 2 1 0

Oradb2 oradev21 CL1-D 2 1 h1

Oradb3 oradev31 CL1-D 2 1 h2

Oradb4 oradev41 CL1-D 2 1 h3

Cascade function and configuration files

Each volume in a cascading connection is described by an entry in the configuration definition
file on the each HORCM instance, and each connection of the volume is specified by mirror
descriptor. In the case of a Business Copy/Continuous Access Synchronous cascading connection,
too, the volume is described in the configuration definition file on the same instance. The following

Examples of RAID Manager configurations

87

Advertising
This manual is related to the following products: