Is the drive module fault/uid led blinking amber – HP 2000SA G2-Modular-Smart-Array User Manual

Page 53

Advertising
background image

HP 2000sa G2 Modular Smart Array User Guide

53

Are both drive module LEDs off (Online/Activity and Fault/UID)?

Is the drive module Fault/UID LED blinking amber?

Is a connected host port’s Host Link Status LED off?

Answer

Possible Reasons

Actions

Yes

•

There is no power.

•

The drive is offline.

•

The drive is not

configured.

•

Check that the drive is fully inserted and latched in place,

and that the enclosure is powered on.

Answer

Possible Reasons

Actions

No, but the

Online/Activity

LED is blinking.

The drive is rebuilding.

No action required.

CAUTION:

Do not remove a drive that

is rebuilding. Removing a drive might

terminate the current operation and

cause data loss.

Yes, and the

Online/Activity

LED is off.

The drive is offline. A predictive failure

alert may have been received for this

device.

•

Check the event log for specific information

regarding the fault.

•

Isolate the fault.

•

Contact an authorized service provider for

assistance.

Yes, and the

Online/Activity

LED is blinking.

The drive is active, but a predictive

failure alert may have been received

for this device.

•

Check the event log for specific information

regarding the fault.

•

Isolate the fault.

•

Contact an authorized service provider for

assistance.

Answer Possible Reasons

Actions

No

System functioning properly.

No action required.

(see

Link LED

note: page 41)

Yes

The link is down.

•

Check cable connections and reseat if necessary.

•

Inspect cables for damage.

•

Swap cables to determine if fault is caused by a

defective cable. Replace cable if necessary.

•

Verify that the switch, if any, is operating properly. If

possible, test with another port.

•

Verify that the HBA is fully seated, and that the PCI slot is

powered on and operational.

•

In SMU, review event logs for indicators of a specific

fault in a host data path component.

•

Contact an authorized service provider for assistance.

•

See

Isolating a host-side connection fault

on page 57.

Advertising