Interpreting Agent Email Messages

59

Command Console V2.5 User Guide

Mapping State Change Digits to RAID System Components

Each of the 11 digits in the state change field can be mapped to a RAID system
component.

Table 11

lists the digits and their relationship.

The First Digit of the State Change Field

(Overall RAID System)

The first digit in the state change field reports state changes in the overall RAID
system.

Example:

WARNING: -
Suncity HSG80 12000000000 HSG80 disks(disk21100:2)(SP_MONITOR:
MonitorSubsys)

The first digit can have one of two values:

0—Everything is fine.
1—Something has changed state.

Table 11: State Change Digit Position and Corresponding RAID System Component

State Change Digit Position

Corresponding RAID System

Component

1

Overall RAID System

2

Disks

3

Power Supply

4

Fans

5

Battery

6

Temperature

7

This Controller

8

Communications LUN

9

Other Controllers

10

External Factors

11

Logical Units