External Storage XP for the XP10000/XP12000

6.

For mainframe emulation types, use Volume Management to resize the volume or perform the Write to

Control Blocks operation (see the HP StorageWorks LUN Configuration and Security Manager XP User

Guide for the XP10000/XP12000).

7.

Define alternate paths between the external disk array and the local disk array (”

Defining alternate

paths

” on page 59).

8.

Use LUN Manager to define paths (see the HP StorageWorks LUN Configuration and Security

Manager XP User Guide for the XP10000/XP12000.

Configuring external disk array LUs, host mode, and ports

This section describes how to configure the MSA external disk array. For other disk arrays, see the

documentation for that external disk array. For further information, see ”

Configuring MSA1000/1500 as

external disk arrays

” on page 98.

You do not need to configure the SAN topology parameters on the MSA disk array. The MSA

automatically detects whether it is connected to the local disk array via a switch or point-to-point

connection, and adjusts its parameters accordingly.
If no LUNs are available on the MSA, you must create them.

1.

Set the channel transfer speed according to the configuration.
Generally, select Auto Negotiation.

2.

Use Selective Storage Presentation to configure the MSA LUs involved with External Storage XP.

Setting port attributes on the local disk arrays

The attribute of any port used for External Storage XP must be set to External.

1.

Click the Port Operation tab on the XP10000/XP12000.

2.

In the Port List, select the port.
To set several ports at one time to External, select all the ports.

3.

Right-click, and select Change to External.
In the Port List, the attribute of the selected port changes to External, and the row of the selected port

appears in blue italics. The rows to be affected appear in the Preset list. To check setting details, select

the setting in the Preset list, right-click, and select Detail. To cancel settings, select the setting in the

Preset list, right-click, and select Delete.

4.

Click Apply. A confirmation message appears.

5.

Click OK.
The setting of the port attribute is applied to the local disk array, and the new setting appears in the

Port List.