HP Netserver L Server series User Manual
Page 23

Chapter 3
Configuring Mass Storage
17
Hot Swap Subsystem SCSI Address Settings
Switches 4 and 6 determine the SCSI address setting for each shelf in the hot swap
subsystem. Table 3-2 lists the shelf SCSI address for each switch setting.
NOTE
For information on changing the SCSI address setting on the
CD-ROM drive, see the Technical Information Label on the
CD-ROM drive.
Table 3-2. SCSI Address Settings
Upper Cage
Lower Cage
Switch Settings
SCSI Address
Switch Settings
SCSI Address
3 - Off
4 - Off
6 - Off
Shelf 1 = ID 1
Shelf 2 = ID 2
Shelf 3 = ID 3
3 - Off
4 - Off
6 - On
Shelf 4 = ID 4
Shelf 5 = ID 5
Shelf 6 = ID 6
3 - Off
4 - On
6 - Off
Shelf 1 = ID 1
Shelf 2 = ID 0
Shelf 3 = ID 3
3 - Off
4 - On
6 - On
Shelf 4 = ID 4
Shelf 5 = ID 0
Shelf 6 = ID 6
3 - On
4 - Off
6 - Off
Shelf 1 = ID 9
Shelf 2 = ID 10
Shelf 3 = ID 11
3 - On
4 - Off
6 - On
Shelf 4 = ID 12
Shelf 5 = ID 13
Shelf 6 = ID 14
3 - On
4 - On
6 - Off
Shelf 1 = ID 9
Shelf 2 = ID 8
Shelf 3 = ID 11
3 - On
4 - On
6 - On
Shelf 4 = ID 12
Shelf 5 = ID 8
Shelf 6 = ID 14