Commands 14

Display all modules in an enclosure:

vcsu -a report -i 192.168.1.100 -u Administrator -p password -l VCpackage

resetvcm

Log into the specified interconnect bay and restart the Virtual Connect Manager service. This is the same
process as the menu option "Reset VC Manager" from the Virtual Connect user interface.

Item

Description

Syntax

vcsu -a resetvcm -i <IP> -u <USER> -p <PWD>

Parameters:

IP

IPv4 address of the active OA in the enclosure*

USER

Name of the OA user with privileges to access all enclosure interconnect bays. Minimum length

is 1 character. Maximum length is 40 characters.**

PWD

Password of the OA user. Minimum length is 3 characters. Maximum length is 40
characters.**

*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.
**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across

local and all remote enclosures in the Virtual Connect domain.

Example
Reset the modules in an enclosure:

vcsu -a resetvcm -i 192.168.0.100 -u Administrator -p password

supportdump

Log into VC Manager using the supplied credentials and access Virtual Connect to request a support

information (debug dump) download. VCSU saves that file in the current directory as the file name supplied

by Virtual Connect. A functioning VC Manager domain is required for this action.

Item

Description

Syntax

vcsu -a supportdump -i <IP> -u <USER> -p <PWD> -vcu <VCM USER> -vcp <VCM

PASS> -l <LOCATION>

Parameters:

IP

IPv4 address of the active OA in the enclosure*

USER

Name of the OA user with privileges to access all enclosure interconnect bays. Minimum length

is 1 character. Maximum length is 40 characters.**

PWD

Password of the OA user. Minimum length is 3 characters. Maximum length is 40
characters.**

VCM USER

Name of Virtual Connect user with Domain privileges. Required if an enclosure is in a Virtual

Connect domain. Minimum length is 1 character. Maximum length is 31 characters.

VCM PASS

Password for the Virtual Connect user. Minimum length is 3 characters. Maximum length is 31
characters.

LOCATION

Full path, including file name, to save the support dump file. If not provided, VCSU saves the

support dump file to the file name that VCM provides and downloads it to the current directory.

*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.

**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across
local and all remote enclosures in the Virtual Connect domain.