Troubleshooting 18

Troubleshooting

Error messages

Error message

Resolution

This version of the application does not support the
target enclosure

Specify a supported enclosure type.

Unable to get enclosure part number

Check connectivity with the OA, and then restart the update

process.

Another instance of this application is running.
Please wait until all other instances are completed

and try again.

More than one instance of the update utility is attempting to
run on the client. Wait until all other instances are complete,

and then try again.

Unable to initialize Onboard Administrator
interface

Check connectivity with the OA, and then restart the update

process.

Unable to login to the Onboard Administrator.
Please confirm the OA IP address and user

credentials.

Confirm the OA IP address and user credentials.

Invalid option

An invalid option has been specified by the user. Verify the
list of available options for that command.

Invalid -a option

An invalid -a format has been specified by the user. Verify

the list of available commands.

One or more parameters missing

One or more required parameters was not specified. See
the required syntax for the command.

Missing -l option

Specify the required package location.

Invalid -f option

The -f version option can only be used with the update

command. Be sure a valid -f option is specified.

Invalid OA IP address

Provide a valid IP address in the proper format.

Unable to communicate with OA IP
aaa.bbb.ccc.ddd

Check connectivity with the OA and verify that you are

using a valid IP address.

OA username is longer than 40 characters

Enter a valid OA username.

OA user password is greater than 40 characters Enter a valid OA user password.
Invalid bay number

Specify a valid bay number for the target enclosure.

OA firmware version a.bb is not supported

Update the firmware on the target enclosure.

Unable to communicate with Onboard
Administrator. Please confirm validity of the OA IP

address and user credentials.

Confirm the validity of the OA IP address and user

credentials.

Specified Onboard Administrator is not primary

Specify the OA IP address of the primary OA in the target

enclosure.

Unable to get enclosure VC mode information

Log into VC Manager GUI and resolve any errors with VC
Manager. Reset the OA to factory defaults, and then log

into the VC Manager GUI.

Initialization process failed. Firmware update
cannot continue.

Check update requirements, and then try the update again.