Figure 20 Diagram of the drive bays in a HP P4800 and HP P4800 G2

Viewing disk status for the HP P4900 G2

The disks are labeled 1 through 8 in the Disk Setup window (

Figure 21 (page 44)

), and correspond

to the disk drives from top to bottom, left to right (

Figure 22 (page 44)

), when you are looking at

the front of the HP P4900 G2.

Figure 21 Viewing the Disk Setup tab in a HP P4900 G2

Figure 22 Diagram of the drive bays in a HP P4900 G2

Replacing a disk

The correct procedure for replacing a disk in a storage system depends upon a number of factors,
including the RAID configuration, the data protection level of volumes and snapshots, and the
number of disks being replaced. Replacing a disk in a storage system that is in a cluster requires
rebuilding data on the replaced disk.

Replacing a disk in a storage system includes the following basic steps.

•

Planning for rebuilding data on either the disk or the entire storage system (all storage systems)

•

Powering the disk off in the CMC (non-hot-swap storage systems)

•

Physically replacing the disk in the storage system (all storage systems)