HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 23

Advertising
background image

Troubleshooting 23

Error code

Details

VCSU_ERROR_FTP_NOT_READY

The FTP server is not ready.

VCSU_ERROR_FTP_USERNAME_NOT_VALID

The FTP username is not valid.

VCSU_ERROR_FTP_PASSWORD_INVALID

The FTP password is not valid.

VCSU_ERROR_FTP_REJECTED_PASSIVE_MODE

The FTP server rejected passive mode.

VCSU_ERROR_FTP_REJECTED_COMMAND

The FTP server rejected the command.

VCSU_ERROR_FTP_NO_RESPONSE

The FTP server is not responding.

VCSU_ERROR_FTP_RECEIVE_ERROR

An FTP receive error exists.

VCSU_ERROR_FTP_INVALID_IP

Invalid FTP server IP address

VCSU_ERROR_NO_UPDATABLE_MODULES

No target modules are found that can be
updated.

VCSU_ERROR_MODULE_UPDATE_NOT_REQD

The specified module is not required to be

updated.

VCSU_ERROR_MODULE_ACTIVATE_NOT_REQD

The specified module is not required to be

activated.

VCSU_ERROR_MODULE_INFO_NOT_AVAILABLE

The specified module's information is not
available.

VCSU_ERROR_MODULE_NOT_PRESENT

The specified module is not present.

VCSU_ERROR_MODULE_NOT_POWERED_ON

The specified module is not powered on.

VCSU_ERROR_MODULE_NOT_OPERATIONAL

The specified module is not operational.

VCSU_ERROR_ADMIN_PERMISSIONS_REQD

The admin privileges are required to upgrade
specified modules.

VCSU_ERROR_CHECKPOINT_RENAME_FAILED

The checkpoint rename operation failed on the
specified modules.

VCSU_ERROR_VCM_CONFIGURATION_NOT_IN_SYNC

The VC configuration is still not in sync.

VCSU_ERROR_VCM_FAILOVER_FAILED

Failover to backup module failed.

VCSU_ERROR_BAY_CONFIGURATION_FAILED

Unable to configure the bay

VCSU_ERROR_CLI_COMMAND_EXECUTION_FAILED

Unable to execute CLI command on the target
module

VCSU_ERROR_MODULE_NOT_UPGRADABLE

The specified module is not upgradeable.

VCSU_ERROR_MODULE_COMMAND_FAILED

The command on the target module failed.

VCSU_ERROR_RESET_TIME_OUT

The reset on the target module timed out.

VCSU_ERROR_RESET_FAILED

The reset on the target module failed.

VCSU_ERROR_INVALID_MODULEID

The specified module ID is invalid.

VCSU_ERROR_PREVIOUS_UPDATE_NOT_COMPLETETD

A previous firmware update operation on one
or more modules is not complete.

VCSU_ERROR_MULTIPLE_INSTANCE

Another firmware update is running against the

specified OA.

VCSU_ERROR_FC2_FW_EXTRACTION_FAILED

The extraction of the VC FC2 firmware package

failed.

VCSU_ERROR_DOWNGRADE_FROM_MULTIENCLOSURE

A downgrade from a 2.10 multi enclosure
domain is not supported.

VCSU_ERROR_NOT_MULTIENCLOSURE

Invalid module IDs for single enclosure update

VCSU_ERROR_VCM_MODE_RESTORE_FAILED

Failed to restore the VC mode of primary or

backup module

VCSU_ERROR_ACTIVATION_FAILED

Failed to activate one or more modules

VCSU_ERROR_UNINITIALIZED_MUTEX

Invalid mutex found

Advertising