Version – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 16

Advertising
background image

Commands 16

Item

Description

(reboot) modules.

-we

Optional. Specifies the amount of time, in minutes, to wait between activating or
rebooting VC-Enet modules. This command is required for some MPIO/teaming software

on the server blades in the enclosure. The default is 0, or no delay.

-wf

Optional. Specifies the amount of time, in minutes, to wait between activating or
rebooting VC-FC modules. This command is required for some MPIO/teaming software on

the server blades in the enclosure. The default is 0, or no delay.

-cp

Optional. Password for the configuration backup file. Supported in VCM firmware
versions 3.00 and higher. The default is no password.

*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.

Examples
Update multiple modules in an enclosure imported into a VC domain:

vcsu -a update -i 192.168.1.100 -u Administrator -p password -vcu John -

vcp vcPass -l C:\images\vcfw-120.bin

Update a single module in an enclosure not imported into a VC domain:

vcsu -a update -i 192.168.1.100 -u Administrator -p password -l

vcfw121.bin -b 3

Update a single module in an enclosure managed by the VC domain:

vcsu -a update -i 192.168.1.100 -u Administrator -p password -vcu John -

vcp vcPass -l C:\images\vcfw-120.bin -b 3

Perform an update and specify an activation ordering method:

vcsu -a update -i 192.168.1.100 -u Administrator -p password -vcu John -

vcp vcPass -l C:\images\vcfw-120.bin -oe serial -of parallel

Perform an update using a firmware image from a web server address:

vcsu –a update –i 192.168.1.100 –u Administrator –p password –l

http://www.myserver.com/vcfw-120.bin

Perform an update using a firmware image from an FTP server on the network:

vcsu –a update –i 192.168.1.100 –u Administrator –p password –l

ftp://user:[email protected]/vcfw-120.bin

Perform an update of the same firmware version on a degraded module:

vcsu -a update -i 192.168.1.100 -u Administrator -p password -l

C:\images\vcfc-120.bin -f version,health

version

Display the current running firmware version on all modules in a specific target enclosure.

Item

Description

Syntax

vcsu -a version -i <IP> -u <USER> -p <PWD> [-b <BAY>]

Parameters:

IP

IP address of the active OA in the enclosure*

USER

Name of the OA user with privileges to access all enclosure interconnect bays. Minimum

length is 3 characters.

PWD

Password of the OA user. Minimum length is 3 characters.

Advertising