background image

Table 3-3 MAC or WWN address and serial number range compatibility (continued)

VCEM-supported

MAC or WWN or serial number in VC
Domain Group

VC Domain server profiles with MAC
or WWN addresses or serial number
allocated as:

Yes

VCEM-defined or user-defined

VCEM-defined, HP-predefined, or
user-defined

No

Factory

VCEM-Defined, HP-predefined, or
user-defined

The VC Domain configuration must be identical to the VC Domain Group configuration. Verify that
the following items are identical:

•

Interconnect bays location and model

•

Enclosure model

•

Domain settings:
—

Configuration for double density servers (for example, BL2x220c)

—

Configuration for full-height and half-height single density servers (for example, BL460c,
BL480c)

•

Ethernet and iSCSI Flex-10 settings:

—

MAC Cache Failover:

Enable Fast MAC Cache Failover
MAC Refresh Interval

—

IGMP Snooping:

Enable IGMP Snooping
IGMP Idle Timeout Interval

—

Server VLAN Tagging support:

Tunnel VLAN Taggings or Map VLAN Taggings
Force Server connection setting

—

Multiple Network Speeding Settings:

Preferred Link Connections
Preferred Link Connection Speed
Maximum Link Connection
Maximum Link Connection Speed

—

Network SNMP settings:

Read Community
System Contact
IP addresses

•

Fibre Channel SAN Fabric settings:
—

Enables SMI-S

—

Fibre Channel SNMP settings: Read Community, System Contact, and IP addresses

•

Network and Fibre Channel SAN Fabrics uplinks

•

For each single network uplink:
— Network name
— Smart link
— Private Network
— Enable VLAN Tunneling
— State
— Network port location

28