Virtual Connect 3.10 features that must be disabled in a VC Domain to be part of
the VC Domain Group with Virtual Connect firmware 3.0x, 2.3x and 2.1x

NOTE:

To disable any of the FC SAN or Flex-10 iSCSI features, the last connection in the feature

table must be deleted first.

•

Flex-10 iSCSI Connections are not supported.

To disable this feature:

1.

Log on to HP Virtual Connect Manager.

2.

Expand Server Profiles in the navigation pane and select the server profile with Flex-10
iSCSI connections.

3.

Right-click on the last Flex-10 iSCSI connection and select Delete Connection as displayed
in the following figure:

Figure 3-2 Removing Flex-10 iSCSI Connections

4.

Continue selecting the last Flex-10 iSCSI connection until all connections are removed.

Virtual Connect 3.0x features that must be disabled in a VC Domain to be part of
the VC Domain Group with Virtual Connect firmware 2.1x and 2.3x

NOTE:
Keep the following in mind:
•

VC 3.0x features must be disabled in order for the firmware to reside in the same groups as
VC 2.3x or 2.1x firmware versions.

•

All Virtual Connect 2.3x features not supported by VC firmware 2.1x must be disabled.

•

Multi-blade FC servers are not supported.

Do not configure server profiles assigned to multi-blade servers with more FC SAN connections
than the number of Virtual Connect Fibre Channel modules available in the VC Domain. The

Requirements for adding a VC Domain to a VC Domain Group