34

Code

Description

Recommended Action

0074h

CMOS RAM time is
invalid.

Run BIOS Setup if problem persists replace battery, if present. Then replace the
system board.

0075h

Time-base frequency
divider set at
incorrect value.

Reset the system and set BIOS Setup parameter. If the problem persists--replace
CMOS RAM and the battery.

0076h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get

the same error, call the HP Customer Care Center.

0077h

Periodic time update
cycle not occurring.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

0078h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get

the same error, call the HP Customer Care Center.

0079h

CMOS RAM fails to
hold data.

1. Run the BIOS Setup program and reconfigure all settings.

2. If necessary, update the BIOS.

3. Clear the CMOS and rerun configuration. See directions on the technical
reference label or card.

4. Make sure the system board is seated.

5. Check the seating of the voltage regulator module (VRM) if present.

6. Be sure the processor board (if any) is seated.

7. Make sure the CPU chip is seated. (Take ESD precautions.)

8. Make sure the memory elements (DIMMs) are properly seated.

9. Check system fans. If overheating occurs, chip may shut down.

10. If the system ran with temperature high, let it cool for 30 minutes, then
restart.

11. If system repeatedly shows this error, replace the element with the CMOS.

0080h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get

the same error, call the HP Customer Care Center.

0081h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get

the same error, call the HP Customer Care Center.

0082h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get

the same error, call the HP Customer Care Center.

0083h

PCI System Bus
scan test failed.

1. Remove all unnecessary PCI cards and try the test again. If it still fails, make
sure all PCI connectors are seated.

2. Make sure the system board is seated.

3. Check the seating of the voltage regulator module (VRM) if present.

4. Be sure the processor board (if any) is seated.

Advertising