VCEM validates the following components when adding a VC Domain to a VC Domain group,
therefore the VC Domain configuration must be identical to the VC Domain Group configuration.
Verify that the following components are identical:

•

Interconnect bays location and model

•

Enclosure model

•

Domain settings:

Configuration for double density servers (for example, BL2x220c)

◦

◦

Configuration for full-height and half-height single density servers (for example, BL460c,
BL480c)

•

Network Access Groups

◦

Name(s) and networks

•

Ethernet and iSCSI Flex-10 settings:

MAC Cache Failover:

◦

–

Enable Fast MAC Cache Failover

–

MAC Refresh Interval

◦

IGMP Snooping:

Enable IGMP Snooping

–

–

IGMP Idle Timeout Interval

◦

Server VLAN Tagging support:

Tunnel VLAN Taggings or Map VLAN Taggings

–

–

Force Server connection setting

◦

Multiple Network Speeding Settings:

Preferred Link Connections

–

–

Preferred Link Connection Speed

–

Maximum Link Connection

–

Maximum Link Connection Speed

◦

Network SNMP settings:

Read Community

–

–

System Contact

–

IP addresses

◦

Port Throughput Statistics

◦

VLAN Capacity

–

Legacy VLAN capacity or Expanded VLAN capacity

•

Fibre Channel SAN Fabric settings:

Enables SMI-S

◦

◦

Fibre Channel SNMP settings: Read Community, System Contact, and IP addresses

•

Network and Fibre Channel SAN Fabrics uplinks