Using chart styles – HP XP Performance Advisor Software User Manual

Page 285

Advertising
background image

points available when the chart is initially updated for 5 minutes. The data points appear in
the next update cycle only for the delta duration.

When you click Start Updating, the chart re-renders itself to show the new values that are
collected from the host agent. The Start Time displays the time when the automatic update
started, and the End Time displays Continuous Update. It implies that HP XP P9000 Performance
Advisor continuously updates the chart with the newest data points till the time you click Stop
Updating. Then, HP XP P9000 Performance Advisor stops the automatic re-rendering of the
chart. The End Time displays the time till when the chart was last updated.

Date/Time Filters:

The Preset option in the Chart Settings

Time Frame section displays the following date filters:

1 hour

6 hours

12 hours

1 day

1 week

Custom: Click to select the duration (start and end date) from the calendar and then click
Update. The duration is for when you want to view the performance data of the selected
components.

By default, the data points collected in the last one hour of the management station's time are
displayed, if you do not specify a particular duration.

Last 10 Collections:

Click Last 10 Collections in the Chart Settings

Time Frame section to view only the last 10

data points plotted in the performance graph.

Using chart Styles

The following are the different chart styles that you can use on the performance graphs in the Chart
Work Area:

Time Line

Moving Average

Line Plus Moving Average

Time Line No Breaks

Select any of the above from the Chart Style list in the Chart Settings section.

Time Line Chart Style

Time Line chart style (default) enables you to view the plotting of data points for a fixed time interval.
In addition, when data points for multiple metrics are plotted with different collection frequencies,
their relationships with the time intervals are displayed correctly.

Only data points that are collected during the specified interval are retrieved from the database
and plotted on the graph. Data points are not plotted for intervals of time where data collection
has failed. Hence, there can be discontinuity in the graph plotted. In the sense, the graph for that
particular duration displays a blank graph area, indicating a failure in data collection. The data
points are plotted again once data collection resumes.

Moving Average Chart Style

The Moving Average chart style enables you to view the average performance of the selected
components for a specified time interval. The current average (Moving Average) value is calculated

Plotting charts 285

Advertising
This manual is related to the following products: