Lo100 serial port configuration, Using tcp/ip over ethernet management port – HP Lights-Out 100 Remote Management User Manual

Page 13

Advertising
background image

Configuration 13

f.

Press the down arrow (

) key to scroll to the LAN Interface submenu. Press the Enter key.

g.

Confirm the following settings:
BMC Telnet Service: [Enabled]
BMC Ping Response: [Enabled]
BMC HTTP Service: [Enabled]

6.

Press the F10 key to save and exit.

LO100 serial port configuration

1.

Power on the server by pressing the Power On/Off button on the front panel.

2.

When POST displays the message,

ROM-Based Setup

, press the F10 key. If the server has an

administrator password configured, the system prompts you to enter the password. If the server does
not have a password configured, the main screen of the BIOS Setup Utility appears.

3.

On ProLiant DL140 G2 and ProLiant DL145 G2 servers:

a.

Press the right arrow (

) key to navigate to the Advanced menu.

b.

Press the down arrow (

) key to scroll to the Console Redirection menu. Press Enter.

c.

Press the Enter key to toggle between Enabled and Disabled. Select Enabled for the console

redirection option.

d.

Review the serial port settings, and ensure that the settings match the serial port communications
software settings used to connect to LO100.

4.

On ProLiant ML150 G2 servers:

a.

Press the right arrow (

) key to navigate to the Advanced menu.

b.

Press the down arrow (

) key to scroll to the Console Redirection menu. Press Enter.

c.

Press the Enter key to toggle between Disabled, On-board Com A, and On-board BMC/VSI.

Select On-Board BMC/VSI for the console redirection option.

d.

Review the serial port settings, and ensure that the settings match the serial port communications
software settings used to connect to LO100.

5.

On ProLiant ML110 G3 servers:

a.

Press the right arrow (

) key to navigate to the Advanced menu.

b.

Press the down arrow (

) key to scroll to the BIOS Serial Console Configuration menu. Press the

Enter key. Select Bios Serial Console, and press the Enter key to toggle between Enabled and

Disabled. Select Enabled.

c.

Press the down arrow (

) key to scroll to and select Serial Over LAN (SOL). Press the Enter key to

toggle between Enabled and Disabled. Select Enabled.

6.

Press the Esc key to return to the previous screen, or press the F10 key to save the changes and exit
Setup.

Using TCP/IP over Ethernet management port

The LO100 LAN port can be accessed from two different Ethernet ports: the dedicated 10/100 LO100

management port or through a side-band connection with the second LOM (NIC2).