3.

Under

Site Monitor

, specify

Missed Status Responses

to identify the number of responses from a server that can be

missed before the Management Console considers communications lost and updates the icons. Valid values are between

1

and

100

. The default setting is

2

.

4.

Under

Connection Monitor

, specify

Missed Status Responses

to identify the number of responses from a server that

can be missed before the Management Console considers communications lost and updates the icons and colors. Valid
values are between

0

and

1000

. The default setting is

5

.

5.

Click

OK

to save the settings.

Monitoring the message window

In addition to the statistics and status shown in the Management Console, you can also open a message window to view
Storage Mirroring processing alerts. These alerts include notifications, warnings, and errors.

1.

Open a new message window by using any of the following methods:

‹

Right-click on the server that you want to monitor in the left pane and select

New

,

Message Window

.

‹

Select the Message Window icon from the toolbar.

‹

Select

Monitor

,

New Message Window

and identify the

Server

that you want to monitor.

NOTE:

If the

Site Monitor

and

Connection Monitor

settings are different, at times, the icons and color may not

be synchronized between the left and right panes.

NOTE:

The standard appearance of the message window is a white background. If your message window has a gray
background, the window is inactive. The Management Console may have lost communications with that server,
for example, or you may no longer be logged into that server.

The message window is limited to the most recent 1000 lines. If any data is missing an entry in red will indicate
the missing data. Regardless of the state of the message window, all data is maintained in the Storage Mirroring
log on the server.