Menu item

Sub-menu item

Sub-menu item

Values

Description

ITB Contact/
Alienation

Tray 2 Pickup Motor

Tray 2 Pickup
Solenoid

Tray 3 Pickup Motor

Tray 3 Pickup
Solenoid

Tray 4 Pickup Motor

Tray 4 Pickup
Solenoid

Tray 5 Pickup Motor

Tray 5 Pickup
Solenoid

Duplexer Reverse
Motor

Duplexer Feed Motor

Duplexer ReFeed
Motor

Paper Transport
Motor

Repeat

Once

(Default)

Continuous

Determines the number of times the test runs.

Print/Stop Test

Continuous value
from 0 to 60,000
milliseconds.
Default: 0

Isolate faults by stopping the device during
the print cycle and observing where in the
process the image degrades. To run the test,
specify a stop time. The next job that is sent
to the device stops at the specified time in the
process.

Color Band Test

Test Page

Print

Prints a page that helps identify arcing in the
high-voltage power supplies.

Copies

Continuous value
from 1 to 30.

Default: 1

Specify the number of copies to print for the
Color Band test

Scanner Tests

Lower Lamp

Sensors

ADF Input Motor

ADF Input Reverse

Flatbed Motor

ADF Read Motor

A service technician can use this menu item
to diagnose potential problems with the
device scanner.

Table 2-17