HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 12

Advertising
background image

Commands 12

Item Description

Syntax

vcutil -a update -i <IP> -u <USER> -p <PWD> -l <FILE> [-b <BAY>]

[-f <FORCE>] -vcu <VCM USER> -vcp <VCM PASS> [-q] [-oe <ORDER>] [-

of <ORDER>] [-we <MINUTES>] [-wf <MINUTES>]

Parameters:

IP

IP address of the active OA in the enclosure*

USER

Name of the OA user with privileges to access all enclosure interconnect bays

PWD

Password of the OA user

FILE

Full path to the Virtual Connect package on the local computer or supported remote server

BAY

Optional. The bay number of the target module. If not specified, the default is all supported
modules. The BAY parameter is only supported for single-enclosure Virtual Connect

domains and for enclosures that are not in a Virtual Connect domain. Enclosures in a Multi-
Enclosure Domain have all modules updated regardless of the BAY parameter.

FORCE

Optional. Comma separated list of force operations under certain conditions:

version—Allow an update of the same or older firmware versions.

health—Allow an update on a module with failed or degraded health.

VCM USER

Name of the Virtual Connect user with Domain privileges. This command is required if an

enclosure is in a Virtual Connect domain.

VCM PASS

Password for the Virtual Connect user

-q

Optional. Specifies that the firmware update does not prompt for confirmation before
updating, and uses the default answer for the confirmation (YES).

-oe

Optional. Specifies VC-Enet module activation order. The following activation order
methods are supported:

parallel—All modules are activated at the same time.

odd-even—(Default) All modules on the backup VCM side are activated first, then all

modules on the primary VCM side except the primary VCM, then the primary VCM
itself.

serial—Modules are activated one at a time starting with the highest numbered bay.

manual—Modules are updated but not activated. Use the VC Manager GUI or OA

GUI to activate (reboot) modules.

-of

Optional. Specifies VC-FC module activation order. The following activation order methods

are supported:

parallel—All modules are activated at the same time.

odd-even—All modules in odd-numbered bays are activated first, and then modules in

even-numbered bays are activated.

serial—(Default) Modules are activated one at a time starting with the highest

numbered bay.

manual—Modules are updated but not activated. Use the OA GUI to activate (reboot)

modules.

-we

Optional. Specifies the amount of time, in minutes, to wait between activating or rebooting

VC-Enet modules. This command is required for some MPIO/teaming software on the server

blades in the enclosure. The default is 0, or no delay.

-wf

Optional. Specifies the amount of time, in minutes, to wait between activating or rebooting

VC-FC modules. This command is required for some MPIO/teaming software on the server
blades in the enclosure. The default is 0, or no delay.

Advertising