Utp cable specifications, Rj-45 pinouts and crossover function, 11 rj-45 pinouts and crossover function – HP NC340T PCI-X Quad-port Gigabit Server Adapter User Manual

Page 11

Advertising
background image

Specifications 11

Specification Value

Agency Approvals

USA: FCC (CFR 47 part 15) and UL 60950
Canada: ICES-003 and CSA 60950
Japan: VCCI
Korea: MIC (RRL), EMC Registration
Australia: ACA, AS/NZS3548/EN55022:1998 (CISPR 22), EN55024:1998
European Union: EN 55022:1998 (CISPR 22), EN 55024:1998, and IEC
60950:1999 (EN 60950:2000)

Safety Compliance

UL Mark (US and Canada)
CE Mark
EN 60590

UTP cable specifications

To connect to the network, the NC340T uses the following cable for 1000Base-T transmission:

CAT5 UTP or better twisted-pair

22-26 AWG, 100

@ 1 MHz

EIA/TIA 568a or EIA/TIA 568b

NOTE:

For Gigabit over copper installations, CAT5 UTP or better 1000Base-T cable must

comply with the IEEE 802.3ab 1000Base-T standard. For new installations, CAT5e (enhanced

CAT5) or better cable is recommended. Maximum distances for Gigabit over copper cable are

100 meters (328 feet).

RJ-45 pinouts and crossover function

The Ethernet standard also specifies that each segment implement a crossover function to connect the

transmitter of one device to the receiver of a device at the other end, and vice-versa. The crossover

function may be implemented internally at the hub or switch or externally through the twisted-pair media.

10/100 pinouts using internal, straight-through crossover

If the crossover function is implemented internally, the port is labeled MDI-X (Medium Dependent Interface-

Crossover). When an MDI-X port is connected to an MDI port, the twisted pair media should be wired

straight-through using the physical pinouts indicated.

Pin

Function Color

match

Function Pin

1 TD+ Orange

TD+ 1

2 TD- Orange/White

TD- 2

3 RD+ Green

RD+ 3

4

Blue/White

4

5

Blue

5

6 RD- Green/White

RD- 6

Advertising