Comparison of raid methods, Choosing a raid level, 7 summary of raid methods – HP StorageWorks 1000 Modular Smart Array User Manual

Page 50: 8 choosing a raid level

Advertising
background image

50

Storage overview

Comparison of RAID methods

Table 7

summarizes important features of the different RAID levels.

Choosing a RAID level

Use

Table 8

to help you determine the best RAID level for your environment.

Table 7

Summary of RAID methods

RAID 0

RAID 1+0

RAID 5

RAID 6

Alternative name

Striping

Mirroring

Distributed Data

Guarding (DDG)

Advanced Data

Guarding (ADG)

Usable drive space*

100%

50%

67% to 93%

50% to 96%

Usable drive space

formula

n

n/2

(n-1)/n

(n-2)/n

Minimum number of

physical drives

1

2

3

4

Tolerates physical drive

failure?

No

Yes

Yes

Yes

Tolerates simultaneous

failure of more than

one physical drive?

No

Only if no two failed

drives are in a mirrored

pair

No

Yes

Read performance

High

High

High

High

Write performance

High

Medium

Low

Low

Relative cost

Low

High

Medium

Medium

*Values for usable drive space are calculated with these assumptions:

•

All physical drives in the array have the same capacity.

•

Online spares are not used.

•

No more than 14 physical drives are used per array for RAID 5.

•

No more than 56 drives are used with RAID 6.

Table 8

Choosing a RAID level

Most important characteristic

Also important

Suggested RAID level

Fault tolerance

Cost effectiveness

RAID 6

I/O performance

RAID 1+0

Cost effectiveness

Fault tolerance

RAID 6*

I/O performance

RAID 5 (RAID 0 if fault tolerance is

not required)

I/O performance

Cost effectiveness

RAID 5 (RAID 0 if fault tolerance is

not required)

Fault tolerance

RAID 1+0

Advertising
This manual is related to the following products: