Cache navigation path, Cache, Navigation path – HP XP P9000 Performance Advisor Software User Manual

Page 271

Advertising
background image

The applicable metrics are displayed in the Available Metrics Choose Metric Category list. Select the
metrics at the component type or the individual component levels, or both to view the related
performance graphs in the Chart Work Area. For a description of these metrics, see

Metric Category,

metrics, and descriptions

” on page 439.

The following table provides the default set of metric categories that are displayed in the Available
Metrics Choose Metric Category list for the XP and the P9000 disk arrays. The Yes and No under For
the XP disk arrays and For the P9000 disk arrays columns indicate whether the particular default
metric is applicable for that XP or P9000 disk array.

For P9000 disk arrays

For XP disk arrays

Most used default metric cat-
egory

Front-end category

Yes

Yes

Frontend IO Metrics

Front-end

Yes

Yes

Frontend IO Metrics

Port

No

Yes

Utilization Metrics

MP

No

Yes

Utilization Metrics

CHA

IMPORTANT:

At the Front-end main category level, the Maximum Port IO/s – Frontend and the Maximum Port
MB/s – Frontend metrics provide the respective maximum I/Os and MB/s of data throughput of
all the ports in the selected XP or the P9000 disk array. These values are the maximum of the last
collection interval. For example, if the port I/O collection interval is set to two minutes, the Max-
imum Port IO will be calculated as the maximum value over the two minute collection interval.

When you plot the performance data points for a port ID, the associated port type is also displayed
in the legend for the selected port ID (example: (53046, CL2A (Fibre (Target)), Total).

Related Topics

Cache navigation path

” on page 271

MP Blades navigation path

” on page 273

Back-end navigation path

” on page 275

Pools navigation path

” on page 278

Snapshot Pool navigation path

” on page 282

Replication Volumes navigation path

” on page 284

LUSE navigation path

” on page 285

Host Groups navigation path

” on page 287

Ext-RG(s) navigation path

” on page 291

Drive types navigation path

” on page 292

Custom groups navigation path

” on page 293

Cache navigation path

The Cache main category comprises of individual CLPR partitions for the selected XP or P9000 disk
array (Cache > Individual CLPRs). The following image is an example for an XP disk array and shows
the CLPRs under the XP disk array Cache.

HP StorageWorks P9000 Performance Advisor Software User Guide

271

Advertising