Nmi functionality – HP ProLiant DL380 G6 Server User Manual

Page 15

Advertising
background image

Component identification 15

Position

Default

Function

S3

Off

Reserved

S4

Off

Reserved

S5

Off

Off = Power-on password is enabled.
On = Power-on password is disabled.

S6

Off

Off = No function

On = Clear NVRAM

S7

—

Reserved

S8

—

Reserved

S9

—

Reserved

S10

—

Reserved

When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all
system configuration settings from both CMOS and NVRAM.

CAUTION:

Clearing CMOS and/or NVRAM deletes configuration information. Be sure to

properly configure the server or data loss could occur.

NMI functionality

An NMI crash dump enables administrators to create crash dump files when a system is hung and not

responding to traditional debug mechanisms.
Crash dump log analysis is an essential part of diagnosing reliability problems, such as hangs in operating

systems, device drivers, and applications. Many crashes freeze a system, and the only available action for
administrators is to cycle the system power. Resetting the system erases any information that could support

problem analysis, but the NMI feature preserves that information by performing a memory dump before a

hard reset.
To force the OS to invoke the NMI handler and generate a crash dump log, the administrator can do any of

the following:

•

Short the NMI jumper pins

•

Press the NMI switch

•

Use the iLO Virtual NMI feature

For additional information, see the whitepaper on the HP website

(

http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00797875/c00797875.pdf

).