Source physical server prerequisites, Source virtual machine prerequisites, Destination physical server prerequisites – HP Insight Control Software for Linux User Manual

Page 38

Advertising
background image

Verify compliance with all minimum prerequisites. For more information, see

“Minimum source

server prerequisites for all migrations” (page 35)

.

Make sure that the 32–bit version of glibc is installed. The 32–bit version of glibc is
required to run the Linux server migration Source Agent. The library is present by default on
32–bit Linux installations, but you might need to install it manually on 64–bit Linux systems.
The 32–bit version of glibc is available on your Linux OS installation CD/DVD.

If X–Windows is configured on the source server, make sure that the 32–bit version of the
libXtst runtime library is installed.

Source physical server prerequisites

If you are migrating from a source physical server, verify that the following prerequisites are
completed:

Comply with all minimum prerequisites as listed in

“Minimum source server prerequisites for

all migrations” (page 35)

.

Make sure that PermitRootLogin and PasswordAuthentication are set to Yes in the
/etc/ssh/sshd_config

file and that the sshd service is running.

Make sure that GRUB Boot Loader is the primary boot loader on the source server.

Source virtual machine prerequisites

If you are migrating from a source virtual machine, verify that the following prerequisites are
completed:

Comply with all minimum prerequisites as listed in

“Minimum source server prerequisites for

all migrations” (page 35)

.

Make sure that PermitRootLogin and PasswordAuthentication are set to Yes in the
/etc/ssh/sshd_config

file and that the sshd service is running.

Make sure that GRUB Boot Loader is the primary boot loader on the source server.

Remove guest tools.

Destination physical server prerequisites

If you are migrating to a destination physical server, verify that the following prerequisites are
completed:

Configure the primary storage controller with drives attached.

Connect and configure the NIC cards.

Manually boot the destination server with the Insight Control server migration ProLiant Boot
CD ISO and make sure that it is running the migration Agent.

Select the Auto Boot option in step 3 of the migration wizard to automatically boot the
destination server with Insight Control server migration ProLiant Boot CD ISO.

NOTE:

For Gen8 servers, Manual Boot option is not supported.

38

Migrating the servers