Showing and clearing the fault log, External logging, Hp apm fault messages – HP ProLiant SL2500 Scalable System User Manual

Page 35

Advertising
background image

Logging 35

Showing and clearing the fault log

To show the fault log, enter SHOW FAULTS.
As an example, the following text might appear on screen:

> show faults

May 4 19:43:43 APM-D4C9EFCB01CA system.0: Power Manager Power Supply 1 is

non operational

May 5 01:42:20 APM-D4C9EFCB01CA system.0: Timeout waiting for Dist. Module

mutex on Power Manager port 3

May 6 03:51:16 APM-D4C9EFCB01CA system: Failed login attempt with user

'Administrator' from 192.168.1.1

To clear the fault log, enter CLEAR FAULTS.

External logging

To show the syslog server address configuration information, enter SHOW SYSLOG.
To set the syslog server address configuration, enter SET SYSLOG x.x.x.x.
Using an existing syslog server provides:

Redundant copy of events and logs

No limits to number of events that can be logged

HP APM fault messages

Fault logged message

Description

There was an error transferring the file,

image upgrade not performed

Error occurred during firmware upgrade.

Error upgrading firmware image

Firmware image not upgraded due to an error.

Distribution Module on Power Manager

port X has excessive errors and has been
marked as failed

RS-485 port is having excessive errors and has failed.

Distribution Module port X on Power

Manager port Y has excessive errors and
has been marked as failed

RS-485 port is having excessive errors and has failed.

Transmit failed to write

Hardware error transmitting a packet.

Read error on UART

Hardware error receiving a packet.

Power Manager Power supply 1 is non

operational

Power supply in slot 1 is not supplying power to the HP APM chassis.
There is a 20 second delay in detecting a power supply status

change.

Power Manager Power supply 2 is non

operational

Power supply in slot 2 is not supplying power to the HP APM chassis.

Firmware update to Distribution Module,

port X failed, retry Y being attempted

While upgrading the firmware on a Power Manager Distribution
Module, an error occurred. Retry being attempted.

Firmware update to Distribution Module,
port X - all retries, failed, giving up

While upgrading the firmware on a Power Manager Distribution
Module, too many errors occurred and the operation has been
terminated.