Troubleshooting, Alert messages, Devices not discovered – HP ProLiant SL2500 Scalable System User Manual

Page 74

Advertising
background image

Troubleshooting 74

Troubleshooting

Alert messages

The following messages appear in HP APM.

Message

Where this issue occurs

Required action

There was an error

transferring the file,

image upgrade not

performed.

Firmware upgrade

Verify network connectivity, and then retry the
firmware upgrade.

Error upgrading

firmware image.

Firmware upgrade

Message appears with other logs describing the

actual issue. Review logs to identify, and then
resolve issue.

Dist. Module on Power

Manager Chassis port

<#> has excessive

errors and has been

marked as failed.

All modes of operation

Verify HP APM and HP APM Distribution

Module cabling.

Power Manager Chassis

port <#> on Dist.

Module <#> has

excessive errors and

has been marked as

failed.

All modes of operation

Verify HP APM and HP APM Distribution
Module cabling.

Power Manager Chassis

rendered non

functional, redundant

Power Manager Chassis

is not supported by

this firmware version.

Redundant HP APM inserted
into HP APM enclosure

Remove both HP APM controllers, and then
reinsert only one controller.

The SL enclosure on

Power Manager port

<#>, Dist. Module port

<#> does not support

the Power Manager.

SL Power Management

Controller at the named
location does not support HP
APM.

Update the SL Power Management Controller in

that chassis. If no update is available, the SL
Power Management Controller does not offer
support for HP APM.

For messages not listed, contact HP Support (

http://www.hp.com/support

). For more information, see

"Support and other resources (on page

112

)."

Devices not discovered

If devices are not discovered, perform the following steps:

1.

Check the link and power LEDs.

2.

Check the cables.

3.

Reboot HP APM.

Advertising
This manual is related to the following products: