Toolkit utilities 50

Error code

Error message

Comment or clarification

2839

Cannot migrate logical drive

RAID.

The controller does not support RAID migration, or migration is

not possible with the current controller configuration.

2840

Cannot migrate logical drive
stripe size.

The controller does not support stripe size migration, or
migration is not possible with the current controller

configuration.

2841

Cannot extend logical drive. The controller does not support extension, or the current

controller configuration cannot be extended. For example,

extension is not possible if the array has no free space.

2842

Invalid RAID.

The specified RAID level is invalid or is not possible with the

current configuration.

2843

Invalid size.

The specified size is invalid or is not possible with the current
configuration.

2844

Invalid stripe size.

The specified stripe size is invalid, or not supported by the

current RAID level, or not possible with the current configuration.

2845

Invalid sectors.

The specified MaxBoot setting is invalid or is not possible with
the current configuration.

2846

Cannot change logical drive

sectors.

You cannot change the MaxBoot setting on a configured logical

drive because doing so causes data loss.

2847

Invalid array accelerator
setting.

The specified array accelerator setting is invalid or is not
supported by the current configuration.

2848

Cannot change logical drive

array accelerator setting.

You cannot change the array accelerator setting for the current

controller configuration.

2849

Invalid
ClearConfigurationWithData

Loss parameter.

2850

Controller does not support

RAID Array ID.

2851

Invalid RAID Array ID.

The scripted RAID Array ID is invalid. Use characters from the set

a–z, A–Z, 0–9, !, @, #, *, (, ), ,, -, _, +, :, ., /, and [space]. The

ID cannot end with a space character or exceed the maximum
number of characters allowed by the controller.

2852

Invalid SSP state.

2853

Cannot change SSP settings. —

2854

Invalid SSP adapter ID.

2855

Controller does not support
logical drive SSP states. Use

the SSPState controller

command to set the controller
SSP state.

2856

Controller does not support
controller SSP state. Use the

LogicalDriveSSPState logical

drive command to set SSP
states for each logical drive.

2857

Invalid surface scan delay.

2861

Controller does not support

redundancy settings.

The controller is not redundant or does not support redundancy

settings.

2864

Invalid preferred path mode. The specified value for the preferred path mode is not valid, or

the controller is not available.