Script file options – HP Linux Server Management Software User Manual
Page 38
 
Toolkit utilities 38
ExpandPriority = Low|Medium|High 
SurfaceScanDelay = N 
SSPState = Enable|Disable 
PreferredPathMode = Auto|Manual 
 
; COMMENT: the following five entries are used to optimize the controller 
performance for video 
MNPDelay = 0|1|2|...|60 ; units are minutes, zero indicates disabled 
IRPEnable = Yes|No 
DPOEnable = Yes|No 
ElevatorSortEnable = Yes|No 
QueueDepth = 2|4|8|16|32|Auto 
 
Array = A|B|C|D|E|F|G|...Z|a|b|c|d|e|f 
 
OnlineSpare = None | N | Port:ID,Port:ID... | Box:Bay,Box:Bay... | 
Port:Box:Bay,Port:Box:Bay,... ; COMMENT: These values are available only in
Custom method mode. In Auto method mode, the choices are Yes|No. 
 
Drive = * | N | Port:ID,Port:ID... | Box:Bay,Box:Bay... | 
Port:Box:Bay,Port:Box:Bay,... 
 
DriveType = SCSI | SAS | SATA 
 
LogicalDrive = 1|2|3|...32 
RAID = 0|1|5|50|6|60|adg|auto ; COMMENT: RAID 6 and 60 are only available when 
SAAP is installed and the license key registered 
ParityGroups = 2|N ; COMMENT: Necessary only for RAID 50 or 60. N > 2 
Size = [N]|Max 
Sectors = 32|63 
StripeSize = 8|16|32|64|128|256 
ArrayAccelerator = Enable|Disable 
LogicalDriveSSPState = Enable|Disable 
SSPAdaptersWithAccess = [N],[N]...|None 
PreferredPath = 1|2 
 
HBA_WW_ID = WWN 
ConnectionName = UserDefinedName 
HostMode = Default | Windows | Windows(degrade | openVMS | Tru64 | Linux | 
Solaris | Netware | HP | Windows Sp2 ; COMMENT: The Windows(degrade value
must be entered as written.
Script file options
Options in ACU script files are divided into the following categories: