Command Interpreter

HP AutoSYNC User’s Guide522580-016

8-34

ALTER MONITOR

a process priority (in the range of 1 to 199) for the monitor process

The PRIMARY, BACKUP, and PRIORITY options specify process creation parameters
that are used when starting the monitor process.

ALTER MONITOR

Modifies attributes of an existing monitor process. The changes take effect when the
monitor process is restarted.

These attributes can also be changed using

ALTER MAPDB

.

process-name

the name of a monitor process. The name must have 4 characters.

If omitted, $ZASY is assumed.

BACKUP cpu-number

the CPU number (in the range of 0 to 15) of the backup monitor process.

HOMETERM [ file-name | NONE ]

a home terminal for the monitor process.

If this option is not specified in this command or when the MapDB was created, the
default monitor process hometerm is set to the system console. The monitor
process writes the messages that would normally go to its hometerm to the EMS
collector $0 or to the collector specified through the EMSCOLLECTOR global
parameter.

If NONE is specified or file-name is omitted, the hometerm is re-set to the default
described above.

PRIMARY cpu-number

the CPU number (in the range of 0 to 15) of the primary monitor process.

PRIORITY process-priority

a process priority (in the range of 1 to 199) for the monitor process.

ALTER MONITOR [ process-name ] {, option... }

option is

{ PRIMARY cpu-number

}

{ BACKUP cpu-number

}

{ PRIORITY process-priority

}