Monitoring and Managing the Switch

66

Edge Switch Element Manager User Guide

—

11 Unresponsive node connected to port.

Possible

causes are:

— Hardware problem on switch or on a connected node where ELP

frames are not delivered, the response is not received, or a fabric login
(FLOGI) cannot be received. There may be problems in the switch
SBAR.

— Faulty or dirty cable connection.

— Faulty host bus adapters that do not send out FLOGI within a

reasonable time frame.

—

0x0C ESA Security Mismatch.

Processing of Exchange Security

Attribute Frame detected required security feature mismatch.

—

0x0D Fabric Binding Mismatch.

Fabric Binding is enabled and

detected a switch connection with an incompatible fabric membership list.
Could also be the result of problems delivering EFMD ILS.

—

0x0E Authorization Failure Reject.

The switch on the

other side of the ISL detected a security violation. This switch receives
notification via a generic reject reason code and sets its port to the invalid
attachment state in sympathy.

—

0x0F Unauthorized Switch Binding WWN.

A Switch Binding

error was detected on either an E_Port or F_Port.

—

0x10 Authentication Failure.

ISL Authentication Check

(CHAP) failed. If you wish to allow the connection, update the
authentication lists or disable authentication.

—

0x11 Fabric Mode Mismatch

—A connection was not allowed

because:

— An HP M-Series switch or director attempted to connect to an HP

switch or director running in Open Fabric mode.

— An HP M-Series switch or director running in Open Fabric mode

attempted to connect to another vendor’s switch or director with an
incorrect ELP revision level.

—

0x12 CNT WAN Extension Mode Mismatch

—The ELP

maximum frame sizes were incompatible because one product running in
CNT WAN extension mode attempted to connect to another product
running in a normal mode.