Table 1 Compatible XRC console messages and troubleshooting (continued)

Description

Console message

If the ANTA5107E (RC=9014, REAS=604 or REAS=608) console message
appears during the XADDPAIR operation, the Compatible XRC software
might not be installed on the HP XP7 Storage system.

ANTA5107E (RC=9014, REAS=604 or
REAS=608)

If Compatible XRC is not installed, install it.

If you execute the Compatible XRC EXDDPAIR command from multiple
LPARs using the same CU, the ANTA5107E (RC=352, REAS=1) console
message appears and the command might fail.

ANTA5107E (RC=352, REAS=1)

In this case, execute the Compatible XRC EXDDPAIR command, on multiple
LPARs in another CU, or on the same LPAR in the same CU.

If the ANTX5123W console message is displayed during the RESUME
operation for Compatible XRC pairs, the operation might be unsuccessful.

ANTX5123W

In this case, you must perform the XDELPAIR operation to delete the pairs,
and then perform the XADDPAIR operation to create the pairs again.

If the Compatible XRC pairs are deleted when a number of sidefiles of the
Compatible XRC pairs remain in cache, this message appears, and a

ANTX5124W

time-out error might occur. Deleting the Compatible XRC pairs must not be
performed.

When the time-out error occurs, the XQUERY TSO command or SCDATA
operation must be performed to check that no sidefiles of the Compatible
XRC pairs exist on cache before deleting the Compatible XRC pairs.

Additionally, in the case of a time-out error, the pair information managed
in SDM and DKC might not match. This is because the sessions remain in
DKC though the pair-status in SDM where XDELPAIR was performed is
deleted. Performing the LISTSESS command can check for the sessions. If
you find the remaining sessions, complete the sessions by the TERMSESS
command.

When the XADDPAIR command is performed after completing sessions,
the ANTA5107E (RC=608) message appears, and the XADDPAIR
command might fail to perform. You must perform the XADDPAIR command
again.

This error can occur because of data transmission delay between SDM
and the channel extender.

ANTX8117I DELAY=(***********)

In this case, contact the manufacturer of the channel extender.

This error can occur because of data transmission delay between SDM
and the channel extender.

After the performing of the XQUERY
command, “****” appears in RES CNT
and THD NT.

In this case, contact the manufacturer of the channel extender.

If you resume the Compatible XRC pair when the sidefiles of the Compatible
XRC pair remain on cache in the following condition, the time-out error
occurs. The Compatible XRC pair must not be performed.

Time-out error

The XSUSPEND TSO command was performed to suspend the
pair-volume.

Any failure made the pair-volume suspended.

When the time-out error occurs, the XQUERY TSO command must be
performed to check that no sidefiles of the Compatible XRC pairs exist on
cache before resuming the Compatible XRC pairs. If you delete Compatible
XRC pairs after the time-out error occurs, the session might remain on the
disk controller side. Execute the LISTSESS command to confirm whether
the session remains. If the session remains, execute the TERMSESS
command to terminate the session.

*The device number, CMD, and occurred VOLSER are unique for your system.

Console messages

25