Managing your fabrics, switches, and ports

To set trap levels:

1.

Launch the Switch Admin module as described on

page 43

.

2.

Click the SNMP tab (see

Figure 18

).

Figure 18

SNMP tab

3.

Select a trap level for a recipient from the corresponding Trap Level list in the SNMPv1 and SNMPv3

sections.
The level you select identifies the minimum event level that will prompt a trap.

4.

Click Apply.

Configuring SNMP information

When you configure SNMP information for the Core Switch2/64 or SAN Director 2/128 configured with

two logical switches, the configuration is on a logical-switch basis. This means that for each logical switch,

you must configure SNMP information individually.

To change the systemGroup configuration parameters:

1.

Launch the Switch Admin module as described on

page 43

.

2.

Click the SNMP tab (see

Figure 18

).

3.

Enter a contact name, a description, and a location in the SNMP Information section.

4.

Optional: select the Enable Authentication Trap check box to allow authentication traps to be sent to

the reception IP address.

5.

Click Apply.