Searching for a zone member, Clearing the zoning database – HP Brocade 4Gb SAN Switch for HP BladeSystem c-Class User Manual

Page 112

Advertising
background image

112 Zone administration

The Replace WWN dialog box lists all the zoning elements that include the WWN.

6.

Click an item in the list to select or unselect, and then click Replace to replace the WWN in all the

selected zoning elements.
The former WWN is replaced in the Zone Admin buffer by the new WWN, including within any alias

or zone in which the old WWN was a member.

Searching for a zone member

You can search zone member selection lists for specified strings of text. If you know some identifying

information about a possible member of a zoning entity, you can select the tab and view for that entity

and then search through its member selection list using the Search for Zone Member option. If the target

entity is an alias, zone, QuickLoop, or FA zone, the search domain includes elements like switch names

and domain numbers, port names and “domain, port” addresses, device WWNs, and manufacturer

names, and also any aliases that already have been defined. If the target entity is a configuration, zones,

FA zones, and QuickLoops are also included, along with the elements they contain.

The search starts at the top of the list; when the target element is found, it is also selected in the Member

Selection List so it can be added or its parent or children can be found. By default, the Member Selection

List is searched from beginning to end one time. If you select the wraparound option, the search continues

to loop from the beginning to the end of the Member Selection List.

To search for a zone member:

1.

Launch the Zone Admin module as described on

page 95

.

2.

Select Edit > Search Member.

3.

Enter the zone member name in the Member Name field.
Optional: Narrow the search by selecting one or more of the check boxes, such as Match Case.

4.

Click Next to begin the zone member search.

Clearing the zoning database

Use the following procedure to disable the active zoning configuration, if one exists, and delete the entire

zoning database:

CAUTION:

This action not only disables zoning on the fabric but also deletes the entire zoning database.

This results in all devices being able to communicate with all other devices.

1.

Launch the Zone Admin module as described on

page 95

.

2.

Select Actions > Clear All.
The Disable Config warning opens.

3.

Click Yes to do all of the following:
• Disable the current configuration.

• Clear the entire contents of the Zone Admin buffer.

• Delete the entire persistent contents of the fabric zoning database.

This action is not recoverable.