HP StorageWorks XP Remote Web Console Software User Manual

Page 137

Advertising
background image

External Storage XP user guide 137

Connecting HP 200 Storage Virtualization System as external storage

When connecting an HP 200 Storage Virtualization System (SVS200) as the external array, you must set

the SVS200 port to a host group for Windows hosts (host mode 0C: Windows or host mode 2C: Windows

Extension).
Also, the SVS200 port attribute must be “target” (for an External Storage XP connection) or “RCU target

port” (for a Continuous Access XP connection).

NOTE:

If you are using microcode that does not support the SVS200, the SVS200 is recognized as an

XP12000 Disk Array. To recognize the connected external array as the SVS200, use the microcode

version that supports the SVS200 (which is microcode version 50-07-0X-XX/XX or higher). If you used an

earlier microcode version that does not support the SVS200 to map the SVS200 volumes, delete the

mapping setting, and then change the microcode version to the one that supports the SVS200.

Illegal request

The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume for Business Copy XP,

Continuous Access XP, or another copy program. If the volume is set as a

pair volume, the volume might be protected because of the pair status. If

the volume is protected, change the pair status or delete the pair.

Response error

The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume for Business Copy XP,

Continuous Access XP, or another copy program. If the volume is set as a

pair volume, the volume might be protected because of the pair status. If

the volume is protected, change the pair status or delete the pair.

Cannot detect port

There is a problem with connection to the external array. The following are

possible causes:

The fibre cable is not connected properly.

The topology setting between the external and target ports does not

match.

If the external array is connected through switches, the switches’

settings might not be appropriate.

Check if the fibre cable is connected properly, and use LUN Manager to

set the Fibre Channel port properly.

Hitachi SANtinel may have set LUN security.
Check if LUN security is enabled. If LUN security is enabled, disable LUN

security.

Table 23

Path status and examples of recovery procedures (XP512/XP48 Disk Arrays) (continued)

Path status

Examples of recovery procedures

Advertising
This manual is related to the following products: