HP P2000 G3 FC/iSCSI MSA System User Guide

57

5.

Move the SFP and FC cable to a port with a known good link status.
This step isolates the problem to the external data path (SFP, host cable, and host-side devices) or to the

controller module port.
Is the host link status LED on?
• Yes – You now know that the SFP, host cable, and host-side devices are functioning properly. Return

the SFP and cable to the original port. If the link status LED remains off, you have isolated the fault

to the controller module’s port. Replace the controller module.

• No – Proceed to the next step.

6.

Swap the SFP with the known good one.
Is the host link status LED on?
• Yes – You have isolated the fault to the SFP. Replace the SFP.
• No – Proceed to the next step.

7.

Re-insert the original SFP and swap the cable with a known good one.
Is the host link status LED on?
• Yes – You have isolated the fault to the cable. Replace the cable.
• No – Proceed to the next step.

8.

Verify that the switch, if any, is operating properly. If possible, test with another port.

9.

Verify that the HBA is fully seated, and that the PCI slot is powered on and operational.

10.

Replace the HBA with a known good HBA, or move the host side cable and SFP to a known good

HBA.
Is the host link status LED on?
• Yes – You have isolated the fault to the HBA. Replace the HBA.
• No – It is likely that the controller module needs to be replaced.

11.

Move the cable and SFP back to its original port.
Is the host link status LED on?
• No – The controller module’s port has failed. Replace the controller module.
• Yes – Monitor the connection for a period of time. It may be an intermittent problem, which can

occur with SFPs, damaged cables, and HBAs.

Host-side connection troubleshooting featuring iSCSI host interface ports

The procedure below apples to P2000 G3 MSA controller enclosures configured with 1Gb iSCSI host

interface ports.

1.

Halt all I/O to the storage system.

2.

Check the host activity LED.
If there is activity, halt all applications that access the storage system.

3.

Reseat the cable and inspect for damage.
Is the host link status LED on?
• Yes – Monitor the status to ensure that there is no intermittent error present. If the fault occurs again,

clean the connections to ensure that a dirty connector is not interfering with the data path.

• No – Proceed to the next step.

4.

Move the cable to a port with a known good link status.
This step isolates the problem to the external data path (host cable and host-side devices) or to the

controller module port.
Is the host link status LED on?
• Yes – You now know that the host cable and host-side devices are functioning properly. Return the

cable to the original port. If the link status LED remains off, you have isolated the fault to the

controller module’s port. Replace the controller module.

• No – Proceed to the next step.

5.

Verify that the switch, if any, is operating properly. If possible, test with another port.