HP Integrity NonStop J-Series User Manual

Page 30

Advertising
background image

Installing and Configuring the ACL Tape Drive for the
NonStop NS-Series Server

M8605A and M8606A ACL Tape Drive Installation and User’s Guide 546012-002

3 -8

Configuration

2. Press the Drive 1 LTO Loaded button.

3. Press the Drive Identification button.

4. View the World Wide Port 0 Name number. This number will be used as the

PORTNAME in Step 5.

5. In SCF, issue this command:

SCF> ADD TAPE $tape, SENDTO STORAGE, LOCATION (group, module,
slot), SAC sac-id, PORTNAME 64-bit-portname, LUN lun-id

Example:

SCF> ADD TAPE $TAPE1, SENDTO STORAGE, LOCATION (110,2,3), SAC
1, PORTNAME 50060B00002E0934, LUN 0

6. To start the ACL tape drive on the server, issue this command in SCF:

SCF> START TAPE $tape

Example:

SCF> START TAPE $TAPE1

For complete details about the ADD and START commands, including command
syntax, see the SCF Reference Manual for the Storage Subsystem.

Note. The LUN (logical unit number) for all Fibre Channel tape storage devices directly
attached to the NonStop NS-series server is 0.